Barksdale Series 450X Intelligent Transmitter

Access stock, delivery and price for Barksdale Series 450X Intelligent Transmitter with Barksdale. Barksdale, Series, Barksdale Series, 450X, Barksdale 450X, Series 450X, Barksdale Series 450X
To get an offer now: info@imtekmuhendislik.com
Product number Series 450X
Producer Barksdale

Description: Series 450X ( Barksdale )

Barksdale Series 450X Intelligent Transmitter



Product Name: Barksdale Series 450X Intelligent Transmitter
Product Brand: Barksdale
Product Code: Series 450X
Product Artikel: Barksdale Series 450X Intelligent Transmitter
Barksdale Intelligent Transmitters (BiT), Series 450X is a high pressure, explosion-proof compact transmitter with HART® communication protocol option. HART® enabled sensors can communicate over the legacy two-wire 4-20 mA analog current loops offering smart features like transmitter diagnostics, calibration, and field re-ranging up to 10 times less than calibrated full scale output (10:1 turndown ratio). Three models are available: Series H455X, 4-20 mA output with HART® Comm. Protocol; Series 455X, 4-20 mA output; Series 452X, 1-5 VDC output. These models can be configured with 24-standard pressure ranges from vacuum to 30,000 psi and multiple process connections from 1/4” NPT to 7/16” SAE and HF4 Autoclave high-pressure connections. Series 450X offers hazardous area explosion protection to meet North American, European and international standards with ATEX, IECEx, cULus approvals.  General Specifications* Accuracy (LH & R): at 75°F, Typical ±0.1% of Calibrated FSO (Option [–A1]) ±0.25% of Calibrated FSO (Standard) ±0.5% of Calibrated FSO (Vacuum only [-23]) Temperature Shift: Zero & Span: 0.0125% Per °F over the compensated temperature range Long Term Stability: ±0.2% FSO/year of calibration curve Typical Life Cycle: 100 million cycles Proof Pressure: 2X range for up to 7500 psi models 1.5X range for 7500 - 30000 psi models Input: H455X: 455X*: 452X*: Excitation voltage: 9 to 30 VDC Excitation voltage: 9 to 30 VDC Excitation voltage: 12 to 30 VDC * (SELV, PELV), Class II Power Supply Supply Current: H455X & 455X: 452X: 20 mA max. 20 mA max. Output: H455X: 455X: 452X: Output: 4–20 mA with HART® Protocol Full Scale Span: 20 mA ±1% Zero output: 4 mA ±1% Output: 4–20 mA Full Scale Span: 20 mA ±1% Zero output: 4 mA ± 1% Output: 1–5 VDC Full Scale Span: 5.0 VDC ± 1% Zero output: 1.0 VDC ± 1% Dynamic Response Time: H455X: 455X & 452X:     Enclosure: All welded 300 series stainless steel. IP66 & IP67 and NEMA 4X rated. 316 Stainless Steel (optional) Wetted Parts: Sensor: Fitting: 17-4 PH Stainless steel (more than 10k psi) 316L Stainless steel (up to 10k psi) 17-4 PH Stainless Steel for -UL option (10k psi) 17-4 PH Stainless steel (all ranges) 316L Stainless steel (optional: up to 10k psi) Media General: Corrosive and Acidic: (up to 10,000 psi) Gas, vapor, liquid and viscous fluids [-Z17] 316L Stainless Steel, NACE [-SS] Pressure Connection: 13 available options. Refer to product configurator for available connections and ranges. Electrical Connection: 3 conductors for voltage output series and 2 conductors for current output series, 18 AWG,80” (2 m) long with integral strain relief and case ground (standard). Jacketed cable (optional). Halogen free wires and cable. 3 and 4 pin Deutsch connector (optional) Temperature Ranges: Operating (Ambient): Compensated: Media: Storage: -40 to +176 °F (-40 to +80 °C) 0 to +165 °F (-18 to +74 °C) -40 to +176 °F (-40 to +80 °C) -40 to +185 °F (-40 to +85 °C) Vibration: 10 g’s, 10-500 Hz, MIL-STD 202, Method 204, Cond A. Shock: 50 g’s, 11 mS, MIL-STD 202 Method 213, Cond. G. Approvals: UL: Single Seal: ATEX/IECEx: cULus approved as telemetering equipment for use in hazardous locations (UL File E146589, WYMV, WYMV7) factory sealed, Type 4X, as follows: Class I, Div. 1, Groups A, B, C & D Class II, Div. 1, Groups E, F & G CSA C22.2 No. 61010-1 Certified ANSI/ISA 12.27.01 Certified (for ranges up to 6,800 PSI) CE 0081 EX II 2 G D Ex db IIC T5 Gb Ex tb IIIC T81°C Db, IP66 & IP67 -40° C ≤ Tamb ≤ +80°C, DEMKO 18 ATEX 2084 IECEx UL 18.0090 HART® Protocol: Turndown Ratio: Analog Output Calibration: Sensor Trim: Diagnostics: HART® 7.6 10:1 (Full scale output rangeability) Adjustable zero and span of 4-20mA. Full scale range must be ≥ (calibrated span / 10) Sensor zero and full scale trim Transmitter failure indicated by off-scale analog signals to alarm the user See HART Installation and Operation Manual 272438 for detailed information Compliances: CE, CRN (refer to drawing # 272479 for applicable models) NACE (316L SS wetted material) Electromagnetic Compatibility (EMC) IEC/EN 55011: IEC/EN 61000-4-2: IEC/EN 61000-4-3: IEC/EN 61000-4-4: H455X: 455X & 452X: IEC/EN 61000-4-5: H455X: 455X & 452X: IEC/EN 61000-4-6: Emission & radiated emission for class A limits Electrostatic discharge (ESD) test - contact discharge +/-4 kV, Air discharge +/-8 kV Radiated RF, EM field immunity 80mhz-1ghz, 3v/M EFT (Burst) Test, +/-2 kV EFT (Burst) Test, +/-1 kV Surge Test, +/-1kV  between line and earth ground Surge test not applicable; Class II power supply used at input of the device RF Immunity, 150 kHz – 80 MHz, 3V Weight: 16 Ounces (453 grams) Warranty: 1 year warranty

Barksdale Series 450X Intelligent Transmitter

Other Recommended Products Barksdale