Barksdale Series 433, 435, 436 Non-Incendive Transducer

Access stock, delivery and price for Barksdale Series 433, 435, 436 Non-Incendive Transducer with Barksdale. Barksdale, Series, Barksdale Series, 433,, Barksdale 433,, Series 433,, Barksdale Series 433,
To get an offer now: info@imtekmuhendislik.com
Product number Series 433, 435, 436
Producer Barksdale

Description: Series 433, 435, 436 ( Barksdale )

Barksdale Series 433, 435, 436 Non-Incendive Transducer



Product Name: Barksdale Series 433, 435, 436 Non-Incendive Transducer
Product Brand: Barksdale
Product Code: Series 433, 435, 436
Product Artikel: Barksdale Series 433, 435, 436 Non-Incendive Transducer
Barksdale's 430 Series Non-IncendiveTransducers prevent an explosion from occurring when operated in a Division II environment. Barksdale's 430 Series, non-incendive transducers prevent personal injury and machinery damage by preventing the explosion in the first place. Energy generated within the transducer is of such a low level that intermittently present flammable vapors will not be ignited. External zener barriers are not required in order to meet UL requirements for a non-incendive installation. Three models are available: Series 433 (0-5V), Series 435 (4-20mA) and Series 436 (0-10V). General Specifications* Accuracy (LH & R): ±0.25% FSO at 75°F (±0.5% for vacuum only [-23]) typical Long Term Stability: ±0.5% FSO of calibration curve Typical Life Cycle: 100 million cycles Proof Pressure: 2 times rated pressure or 13,000 psi max. (884 bar), whichever is less Input: 433: 436: 435: Excitation voltage: 11 to 30 VDC Excitation voltage: 14 to 30 VDC Excitation voltage: 12 to 28 VDC Supply Current: 3.0 mA maximum (no load) Min. Load Resistance: 2K ohms (voltage series) Output: 433: 436: 435: Output: 0.5 to 5.5 VDC Full scale output: 5.0 VDC ± 0.8% Zero output: 0.5 VDC ± 0.4% Output: 1 to 11 VDC Full scale output: 10 VDC ± 0.4% Zero output: 1.0 VDC ± 0.2% Output: 4 to 20 mA Full scale output: 16 mA ± 1% Zero output: 4 mA ± 2% Wetted Parts: 17-4 PH (fitting) & 300 stainless steel (sensor) Enclosure: NEMA 4, 300 series stainless steel Pressure Connection: 1/4”-18 NPT male Response Time: 2kHz Electrical Connection: 3 conductor for voltage series and 2 conductor for current series, 24 awg, PVC jacketed, shielded cable, 3 ft. (1 m) long with integral strain relief and case ground (standard). Temperature Ranges: Operating: Compensated: Storage: -40° to 158°F (-40° to 70°C) -40° to 158°F (-40° to 70°C) -40° to 185°F (-40° to 85°C) Temperature Shift: Zero & Span: 0.01% per °F over compensated range Vibration: 15 g’s, 10-2000 Hz, MIL-STD 202 Shock: 50 g’s, 11 ms, MIL-STD 202 Method 213, Cond. G. Approvals: Nonincendive pressure transmitters are UL and cUL approved as telemetering equipment for use in Div. 2 hazardous locations as follows: Class I, Div. 2, Groups A, B, C & D Class II, Div. 2 Groups F & G Agency approval varies by electrical termination type as follows: H5(-E) models are cULus listed in UL File E146589, (WYMV, WYMV7). H3(-E), T4(-E) & T5 (-E) models are cURus recognized components in UL File E146589, (WYMV2, WYMV8). Weight: 433 & 436: 435: 7.4 oz. (221 grams) to 1,000 psi 9.9 oz. (281 grams) 2,000 psi and higher 7.4 oz. (210 grams) to 1,000 psi 9.4 oz. (266 grams) 2,000 psi and higher Warranty: 1 year warranty * See product confi gurator for additional options. Wiring Code MILLIVOLT SERIES - 433 & 436 (T4/T5) (H3/H5) Signal 1 Red + Excitation 3 White + Output 2 Black Common 4 Bare Drain MILLIAMP SERIES - 435 1 Red + Excitation 2 Black - Excitation 4 Bare Case Drain

Other Recommended Products Barksdale