Barksdale Series 450X Intelligent Transmitter

Bitte kontaktieren Sie unser Live-Support-Team für weitere Informationen zu Barksdale Series 450X Intelligent Transmitter. Barksdale, Series, Barksdale Series, 450X, Barksdale 450X, Series 450X, Barksdale Series 450X
Produkte die mit A beginnen: info@imtekmuhendislik.com
Produktnummer Series 450X
Hersteller Barksdale

Description: Series 450X ( Barksdale )

Barksdale Series 450X Intelligent Transmitter



Product Name: Barksdale Series 450X Intelligent Transmitter
Product Brand: Barksdale
Product Code: Series 450X
Product Artikel: Barksdale Series 450X Intelligent Transmitter
Barksdale Intelligent Transmitters (BiT), Series 450X is a high pressure, explosion-proof compact transmitter with HART® communication protocol option. HART® enabled sensors can communicate over the legacy two-wire 4-20 mA analog current loops offering smart features like transmitter diagnostics, calibration, and field re-ranging up to 10 times less than calibrated full scale output (10:1 turndown ratio). Three models are available: Series H455X, 4-20 mA output with HART® Comm. Protocol; Series 455X, 4-20 mA output; Series 452X, 1-5 VDC output. These models can be configured with 24-standard pressure ranges from vacuum to 30,000 psi and multiple process connections from 1/4” NPT to 7/16” SAE and HF4 Autoclave high-pressure connections. Series 450X offers hazardous area explosion protection to meet North American, European and international standards with ATEX, IECEx, cULus approvals.  General Specifications* Accuracy (LH & R): at 75°F, Typical ±0.1% of Calibrated FSO (Option [–A1]) ±0.25% of Calibrated FSO (Standard) ±0.5% of Calibrated FSO (Vacuum only [-23]) Temperature Shift: Zero & Span: 0.0125% Per °F over the compensated temperature range Long Term Stability: ±0.2% FSO/year of calibration curve Typical Life Cycle: 100 million cycles Proof Pressure: 2X range for up to 7500 psi models 1.5X range for 7500 - 30000 psi models Input: H455X: 455X*: 452X*: Excitation voltage: 9 to 30 VDC Excitation voltage: 9 to 30 VDC Excitation voltage: 12 to 30 VDC * (SELV, PELV), Class II Power Supply Supply Current: H455X & 455X: 452X: 20 mA max. 20 mA max. Output: H455X: 455X: 452X: Output: 4–20 mA with HART® Protocol Full Scale Span: 20 mA ±1% Zero output: 4 mA ±1% Output: 4–20 mA Full Scale Span: 20 mA ±1% Zero output: 4 mA ± 1% Output: 1–5 VDC Full Scale Span: 5.0 VDC ± 1% Zero output: 1.0 VDC ± 1% Dynamic Response Time: H455X: 455X & 452X:     Enclosure: All welded 300 series stainless steel. IP66 & IP67 and NEMA 4X rated. 316 Stainless Steel (optional) Wetted Parts: Sensor: Fitting: 17-4 PH Stainless steel (more than 10k psi) 316L Stainless steel (up to 10k psi) 17-4 PH Stainless Steel for -UL option (10k psi) 17-4 PH Stainless steel (all ranges) 316L Stainless steel (optional: up to 10k psi) Media General: Corrosive and Acidic: (up to 10,000 psi) Gas, vapor, liquid and viscous fluids [-Z17] 316L Stainless Steel, NACE [-SS] Pressure Connection: 13 available options. Refer to product configurator for available connections and ranges. Electrical Connection: 3 conductors for voltage output series and 2 conductors for current output series, 18 AWG,80” (2 m) long with integral strain relief and case ground (standard). Jacketed cable (optional). Halogen free wires and cable. 3 and 4 pin Deutsch connector (optional) Temperature Ranges: Operating (Ambient): Compensated: Media: Storage: -40 to +176 °F (-40 to +80 °C) 0 to +165 °F (-18 to +74 °C) -40 to +176 °F (-40 to +80 °C) -40 to +185 °F (-40 to +85 °C) Vibration: 10 g’s, 10-500 Hz, MIL-STD 202, Method 204, Cond A. Shock: 50 g’s, 11 mS, MIL-STD 202 Method 213, Cond. G. Approvals: UL: Single Seal: ATEX/IECEx: cULus approved as telemetering equipment for use in hazardous locations (UL File E146589, WYMV, WYMV7) factory sealed, Type 4X, as follows: Class I, Div. 1, Groups A, B, C & D Class II, Div. 1, Groups E, F & G CSA C22.2 No. 61010-1 Certified ANSI/ISA 12.27.01 Certified (for ranges up to 6,800 PSI) CE 0081 EX II 2 G D Ex db IIC T5 Gb Ex tb IIIC T81°C Db, IP66 & IP67 -40° C ≤ Tamb ≤ +80°C, DEMKO 18 ATEX 2084 IECEx UL 18.0090 HART® Protocol: Turndown Ratio: Analog Output Calibration: Sensor Trim: Diagnostics: HART® 7.6 10:1 (Full scale output rangeability) Adjustable zero and span of 4-20mA. Full scale range must be ≥ (calibrated span / 10) Sensor zero and full scale trim Transmitter failure indicated by off-scale analog signals to alarm the user See HART Installation and Operation Manual 272438 for detailed information Compliances: CE, CRN (refer to drawing # 272479 for applicable models) NACE (316L SS wetted material) Electromagnetic Compatibility (EMC) IEC/EN 55011: IEC/EN 61000-4-2: IEC/EN 61000-4-3: IEC/EN 61000-4-4: H455X: 455X & 452X: IEC/EN 61000-4-5: H455X: 455X & 452X: IEC/EN 61000-4-6: Emission & radiated emission for class A limits Electrostatic discharge (ESD) test - contact discharge +/-4 kV, Air discharge +/-8 kV Radiated RF, EM field immunity 80mhz-1ghz, 3v/M EFT (Burst) Test, +/-2 kV EFT (Burst) Test, +/-1 kV Surge Test, +/-1kV  between line and earth ground Surge test not applicable; Class II power supply used at input of the device RF Immunity, 150 kHz – 80 MHz, 3V Weight: 16 Ounces (453 grams) Warranty: 1 year warranty

Barksdale Series 450X Intelligent Transmitter

Produktvorschläge Barksdale