SICK 1066547 type: GRTE18-N1142 Photoelectric Sensor

Access stock, delivery and price for SICK 1066547 type: GRTE18-N1142 Photoelectric Sensor with SICK. SICK, 1066547, SICK 1066547, type:, SICK type:, 1066547 type:, SICK 1066547 type:
To get an offer now: info@imtekmuhendislik.com
Product number GRTE18-N1142
Producer SICK

Description: GRTE18-N1142 ( SICK )

SICK 1066547 type: GRTE18-N1142 Photoelectric Sensor



Product Name: SICK 1066547 type: GRTE18-N1142 Photoelectric Sensor
Product Brand: SICK
Product Code: GRTE18-N1142
Product Artikel: SICK 1066547 type: GRTE18-N1142 Photoelectric Sensor
FEATURES Sensor/ detection principle Photoelectric proximity sensor, Energetic Housing design (light emission) Cylindrical Thread diameter (housing) M18 x 1 Optical axis Axial Sensing range max. 5 mm ... 550 mm  1) Sensing range 10 mm ... 400 mm  1) Type of light Visible red light Light source PinPoint LED  2) Light spot size (distance) Ø 9 mm (400 mm) Wave length 650 nm Adjustment Potentiometer 1)  Object with 90 % reflectance (referred to standard white, DIN 5033). 2)  Average service life: 100,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple ± 5 V pp   2) Power consumption 30 mA Switching output NPN Output function Complementary Switching mode Light/dark switching Signal voltage NPN HIGH/LOW Approx. V S  / ≤ 3 V Output current I max. 100 mA  3) Response time < 1,000 µs  4) Switching frequency 500 Hz  5) Connection type Cable, 4-wire, 2 m  6) Cable material PVC Circuit protection A  7) B  8) D  9) Protection class III Housing material Metal, Nickel-plated brass and ABS Optics material Plastic, PMMA Enclosure rating IP67 Items supplied Fastening nuts (2 x) EMC EN 60947-5-2 Ambient operating temperature –25 °C ... +55 °C  10) Ambient storage temperature –40 °C ... +70 °C UL File No. E348498 1)  Limit values. Operated in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  At Uv > 24 V or ambient temperature > 49 °C, IA max. = 50 mA. 4)  Signal transit time with resistive load. 5)  With light/dark ratio 1:1. 6)  Do not bend below 0 °C. 7)  A = V S  connections reverse-polarity protected. 8)  B = inputs and output reverse-polarity protected. 9)  D = outputs overcurrent and short-circuit protected. 10)  At U v  <=24V and I A <50mA. CLASSIFICATIONS ECl@ss 5.0 27270903 ECl@ss 5.1.4 27270903 ECl@ss 6.0 27270903 ECl@ss 6.2 27270903 ECl@ss 7.0 27270903 ECl@ss 8.0 27270903 ECl@ss 8.1 27270903 ECl@ss 9.0 27270903 ECl@ss 10.0 27270904 ECl@ss 11.0 27270904 ETIM 5.0 EC001821 ETIM 6.0 EC001821 ETIM 7.0 EC002719 UNSPSC 16.0901 39121528

Other Recommended Products SICK