SICK 1052445 type: GTB6-N1212 Miniature photoelectric sensor

Access stock, delivery and price for SICK 1052445 type: GTB6-N1212 Miniature photoelectric sensor with SICK. SICK, 1052445, SICK 1052445, type:, SICK type:, 1052445 type:, SICK 1052445 type:
To get an offer now: info@imtekmuhendislik.com
Product number GTB6-N1212
Producer SICK

Description: GTB6-N1212 ( SICK )

SICK 1052445 type: GTB6-N1212 Miniature photoelectric sensor



Product Name: SICK 1052445 type: GTB6-N1212 Miniature photoelectric sensor
Product Brand: SICK
Product Code: GTB6-N1212
Product Artikel: SICK 1052445 type: GTB6-N1212 Miniature photoelectric sensor
FEATURES Sensor/ detection principle Photoelectric proximity sensor, Background suppression Dimensions (W x H x D) 12 mm x 31.5 mm x 21 mm Housing design (light emission) Rectangular Sensing range max. 5 mm ... 250 mm  1) Sensing range 35 mm ... 140 mm Type of light Visible red light Light source PinPoint LED  2) Light spot size (distance) Ø 6 mm (100 mm) Wave length 650 nm Adjustment Mechanical spindle, 5 turns 1)  Object with 90 % reflectance (referred to standard white, DIN 5033). 2)  Average service life: 100,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple ± 10 %  2) Power consumption 30 mA  3) Switching output NPN Switching mode Light/dark switching Switching mode selector Selectable via light/dark selector Signal voltage NPN HIGH/LOW Approx. V S  / ≤ 3 V Output current I max. ≤ 100 mA  4) Response time 5) Switching frequency 1,000 Hz  6) Connection type Cable, 3-wire, 2 m  7) Cable material PVC Conductor cross-section 0.14 mm² Circuit protection A  8) B  9) D  10) Protection class III Weight 60 g Housing material Plastic, ABS/PC Optics material Plastic, PMMA Enclosure rating IP67 Items supplied Stainless steel mounting bracket (1.4301/304) BEF-W100-A Ambient operating temperature –25 °C ... +55 °C  11) Ambient storage temperature –40 °C ... +70 °C UL File No. NRKH.E348498 & NRKH7.E348498 1)  Limit values when operated in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  Without load. 4)  At Uv > 24 V, IA max. = 50 mA. 5)  Signal transit time with resistive load. 6)  With light/dark ratio 1:1. 7)  Do not bend below 0 °C. 8)  A = V S  connections reverse-polarity protected. 9)  B = inputs and output reverse-polarity protected. 10)  D = outputs overcurrent and short-circuit protected. 11)  Temperature stability following adjustment +/-10 °C. CLASSIFICATIONS ECl@ss 5.0 27270904 ECl@ss 5.1.4 27270904 ECl@ss 6.0 27270904 ECl@ss 6.2 27270904 ECl@ss 7.0 27270904 ECl@ss 8.0 27270904 ECl@ss 8.1 27270904 ECl@ss 9.0 27270904 ECl@ss 10.0 27270904 ECl@ss 11.0 27270904 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 UNSPSC 16.0901 39121528

Other Recommended Products SICK