HEIDENHAIN LIDA 409 Exposed Linear Encoder

使用产品代码 LIDA 409 访问产品#HEIDENHAIN 的库存,交货和价格信息。 HEIDENHAIN, LIDA, HEIDENHAIN LIDA, 409, HEIDENHAIN 409, LIDA 409, HEIDENHAIN LIDA 409
产品编号 LIDA 409
生产厂家 HEIDENHAIN

Description: LIDA 409 ( HEIDENHAIN )

HEIDENHAIN LIDA 409 Exposed Linear Encoder



Product Name: HEIDENHAIN LIDA 409 Exposed Linear Encoder
Product Brand: HEIDENHAIN
Product Code: LIDA 409
Product Artikel: HEIDENHAIN LIDA 409 Exposed Linear Encoder
Linear scale LIDA 409 Measuring standard Coefficient of linear expansion Steel scale tape with METALLUR scale grating; grating period 20 µm α therm  10 · 10 –6 K –1 Accuracy grade* ±3 µm, ±15 µm 1) Baseline error ≤ ±0.750 µm/50 mm (typical) Measuring length ML* in mm 70 120 170 220 270 320 370 420 520 620 720 820 920 1020 Scale tape from the roll: 2 m,4 m, 6 m Reference marks One at midpoint of measuring length Every 50 mm Mass 31 g/m Scanning head LIDA 48 LIDA 47 Interface   1 V PP  TTL Integrated interpolation * Signal period – 20 µm 5-fold 4 µm 10-fold 2 µm 50-fold 0.4 µm 100-fold 0.2 µm Cutoff frequency –3 dB ≥ 400 kHz – Scanning frequency * – ≤ 400 kHz ≤ 200 kHz ≤ 100 kHz ≤ 50 kHz ≤ 200 kHz ≤ 100 kHz ≤ 50 kHz ≤ 25 kHz ≤ 50 kHz ≤ 25 kHz ≤ 12.5 kHz ≤ 25 kHz ≤ 12.5 kHz ≤ 6.25 kHz Edge separation a 2) – ≥ 0.100 µs ≥ 0.220 µs ≥ 0.465 µs ≥ 0.950 µs ≥ 0.100 µs ≥ 0.220 µs ≥ 0.465 µs ≥ 0.950 µs ≥ 0.080 µs ≥ 0.175 µs ≥ 0.370 µs ≥ 0.080 µs ≥ 0.175 µs ≥ 0.370 µs Traversing speed 2) ≤ 600 m/min ≤ 480 m/min ≤ 240 m/min ≤ 120 m/min ≤ 60 m/min ≤ 240 m/min ≤ 120 m/min ≤ 60 m/min ≤ 30 m/min ≤ 60 m/min ≤ 30 m/min ≤ 15 m/min ≤ 30 m/min ≤ 15 m/min ≤ 7.5 m/min Interpolation error ±45 nm – Limit switches L1/L2 with two different magnets; output signals : TTL (without line driver) Electrical connection Cable, 0.5 m, 1 m or 3 m with D-sub connector (male) 15-pin Cable length See interface description, however limit: ≤ 20 m (with HEIDENHAIN cable) Voltage supply DC 5 V ±0.5 V Current consumption < 130 mA < 150 mA (without load) Vibration 55 Hz to 2000 Hz Shock 6 ms ≤ 500 m/s 2 (EN 60 068-2-6) ≤ 1000 m/s 2 (EN 60 068-2-27) Operating temperature –10 °C to 70 °C Mass Scanning head Connecting cable Connector 20 g (without cable) 22 g/m 32 g * Please select when ordering 1) ±5 µm after linear length-error compensation in the evaluation electronics 2) At a corresponding cutoff or scanning frequency

HEIDENHAIN LIDA 405 Exposed Linear Encoder

HEIDENHAIN LIDA 407 Exposed Linear Encoder

HEIDENHAIN LIDA 409 Exposed Linear Encoder

HEIDENHAIN LIDA 207 Exposed Linear Encoder

HEIDENHAIN LIDA 209 Exposed Linear Encoder

其他推荐产品 HEIDENHAIN