SICK 1041424 type: WTB12-3P1111 Small photoelectric sensor

Access stock, delivery and price for SICK 1041424 type: WTB12-3P1111 Small photoelectric sensor with SICK. SICK, 1041424, SICK 1041424, type:, SICK type:, 1041424 type:, SICK 1041424 type:
To get an offer now: info@imtekmuhendislik.com
Product number WTB12-3P1111
Producer SICK

Description: WTB12-3P1111 ( SICK )

SICK 1041424 type: WTB12-3P1111 Small photoelectric sensor



Product Name: SICK 1041424 type: WTB12-3P1111 Small photoelectric sensor
Product Brand: SICK
Product Code: WTB12-3P1111
Product Artikel: SICK 1041424 type: WTB12-3P1111 Small photoelectric sensor
FEATURES Sensor/ detection principle Photoelectric proximity sensor, Background suppression Dimensions (W x H x D) 15.6 mm x 48.5 mm x 42 mm Housing design (light emission) Rectangular Sensing range max. 20 mm ... 600 mm  1) Sensing range 20 mm ... 600 mm Type of light Infrared light Light source LED  2) Light spot size (distance) 15 mm x 15 mm (200 mm) Wave length 850 nm Adjustment Potentiometer, 5 turns 1)  Object with 90 % reflectance (referred to standard white, DIN 5033). 2)  Average service life: 100,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple ≤ 5 V pp   2) Power consumption 55 mA  3) Switching output PNP Output function Complementary Switching mode Light/dark switching Signal voltage PNP HIGH/LOW > Uv - 2,5 V / ca. 0 V Output current I max. 100 mA Response time ≤ 330 µs  4) Switching frequency 1,500 Hz  5) Connection type Cable, 4-wire, 2 m  6) Cable material PVC Conductor cross-section 0.25 mm² Circuit protection A  7) C  8) D  9) Protection class III Weight 200 g Housing material Metal Optics material Plastic, PMMA Enclosure rating IP66 IP67 IP69K Items supplied 2 x clamps BEF-KH-W12, incl. screws Ambient operating temperature –40 °C ... +60 °C Ambient storage temperature –40 °C ... +75 °C UL File No. NRKH.E181493 & NRKH7.E181493 1)  Limit values when operated in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  Without load. 4)  Signal transit time with resistive load. 5)  With light/dark ratio 1:1. 6)  Do not bend below 0 °C. 7)  A = V S  connections reverse-polarity protected. 8)  C = interference suppression. 9)  D = outputs overcurrent and short-circuit protected. CLASSIFICATIONS ECl@ss 5.0 27270904 ECl@ss 5.1.4 27270904 ECl@ss 6.0 27270904 ECl@ss 6.2 27270904 ECl@ss 7.0 27270904 ECl@ss 8.0 27270904 ECl@ss 8.1 27270904 ECl@ss 9.0 27270904 ECl@ss 10.0 27270904 ECl@ss 11.0 27270904 ETIM 5.0 EC002719 ETIM 6.0 EC002719 ETIM 7.0 EC002719 UNSPSC 16.0901 39121528

Other Recommended Products SICK