SICK 1058175 type: WL9L-3P2432 Photoelectric sensor

Access stock, delivery and price for SICK 1058175 type: WL9L-3P2432 Photoelectric sensor with SICK. SICK, 1058175, SICK 1058175, type:, SICK type:, 1058175 type:, SICK 1058175 type:
To get an offer now: info@imtekmuhendislik.com
Product number WL9L-3P2432
Producer SICK

Description: WL9L-3P2432 ( SICK )

SICK 1058175 type: WL9L-3P2432 Photoelectric sensor



Product Name: SICK 1058175 type: WL9L-3P2432 Photoelectric sensor
Product Brand: SICK
Product Code: WL9L-3P2432
Product Artikel: SICK 1058175 type: WL9L-3P2432 Photoelectric sensor
FEATURES Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation Dimensions (W x H x D) 12.2 mm x 52.2 mm x 23.6 mm Housing design (light emission) Rectangular Mounting hole M3 Sensing range max. 0 m ... 12 m  1) Sensing range 0 m ... 8 m  1) Type of light Visible red light Light source Laser  2) Light spot size (distance) Ø 1 mm (500 mm) Wave length 650 nm Laser class 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11) Adjustment Single teach-in button Special applications Detecting small objects 1)  Reflector PL80A. 2)  Average service life: 50,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple < 5 V pp   2) Power consumption 30 mA  3) Switching output PNP  4) Output function Complementary Switching mode Light/dark switching  4) Output current I max. ≤ 100 mA Response time ≤ 0.5 ms  5) Switching frequency 1,000 Hz  6) Connection type Male connector M12, 4-pin Circuit protection A  7) B  8) C  9) Protection class III Weight 13 g Polarisation filter ✔ Housing material Plastic, VISTAL® Optics material Plastic, PMMA Enclosure rating IP66 IP67 IP69K Ambient operating temperature –10 °C ... +50 °C Ambient operating temperature extended –30 °C ... +55 °C  10)   11) Ambient storage temperature –30 °C ... +70 °C UL File No. NRKH.E181493 1)  Limit values when operated in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  Without load. 4)  Q = light switching. 5)  Signal transit time with resistive load. 6)  With light/dark ratio 1:1. 7)  A = V S  connections reverse-polarity protected. 8)  B = inputs and output reverse-polarity protected. 9)  C = interference suppression. 10)  As of T a  = 50 °C, a max. supply voltage V max.  = 24 V and a max. load current I max.  = 50 mA is permitted. 11)  Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible. SAFETY-RELATED PARAMETERS MTTF D 723 years (EN ISO 13849-1)  1) DC avg 0% 1)  Mode of calculation: Parts-Count-calculation. CLASSIFICATIONS ECl@ss 5.0 27270902 ECl@ss 5.1.4 27270902 ECl@ss 6.0 27270902 ECl@ss 6.2 27270902 ECl@ss 7.0 27270902 ECl@ss 8.0 27270902 ECl@ss 8.1 27270902 ECl@ss 9.0 27270902 ECl@ss 10.0 27270902 ECl@ss 11.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 UNSPSC 16.0901 39121528

Other Recommended Products SICK