SICK 6037496 type: VL180-2P42436 Photoelectric Sensor

Access stock, delivery and price for SICK 6037496 type: VL180-2P42436 Photoelectric Sensor with SICK. SICK, 6037496, SICK 6037496, type:, SICK type:, 6037496 type:, SICK 6037496 type:
To get an offer now: info@imtekmuhendislik.com
Product number VL180-2P42436
Producer SICK

Description: VL180-2P42436 ( SICK )

SICK 6037496 type: VL180-2P42436 Photoelectric Sensor



Product Name: SICK 6037496 type: VL180-2P42436 Photoelectric Sensor
Product Brand: SICK
Product Code: VL180-2P42436
Product Artikel: SICK 6037496 type: VL180-2P42436 Photoelectric Sensor
FEATURES Sensor/ detection principle Photoelectric retro-reflective sensor, Dual lens Housing design (light emission) Cylindrical Housing length 70.2 mm Thread diameter (housing) M18 x 1 Optical axis Axial Sensing range max. 0.05 m ... 7 m  1) Sensing range 0.05 m ... 6 m  1) Type of light Visible red light Light source LED  2) Light spot size (distance) Ø 400 mm (6 m) Angle of dispersion Approx. 4.5° Wave length 645 nm Adjustment Potentiometer, 270° (Sensitivity) 1)  Reflector PL80A. 2)  Average service life: 100,000 h at T U  = +25 °C. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple ± 10 %  2) Power consumption 30  3) Switching output PNP  4) Switching mode Light/dark switching  4) Switching mode selector Selectable via L/D control cable Signal voltage PNP HIGH/LOW Approx. V S  – 1.8 V / 0 V Output current I max. ≤ 100 mA Response time ≤ 0.5 ms  5) Switching frequency 1,000 Hz  6) Connection type Male connector M12, 4-pin Circuit protection A  7) B  8) D  9) Protection class III Weight 18 g Polarisation filter ✔ Housing material Plastic, PBT/PC Optics material Plastic, PMMA Enclosure rating IP67 Items supplied Reflector P250, fastening nuts (2 x) Ambient operating temperature –25 °C ... +55 °C Ambient storage temperature –40 °C ... +70 °C UL File No. NRKH2.E300503 & NRKH8.E300503 1)  Limit values when operated in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  Without load. 4)  Control wire open: dark switching D.ON. 5)  Signal transit time with resistive load. 6)  With light/dark ratio 1:1. 7)  A = V S  connections reverse-polarity protected. 8)  B = inputs and output reverse-polarity protected. 9)  D = outputs overcurrent and short-circuit protected. SAFETY-RELATED PARAMETERS MTTF D 2,006 years DC avg 0% CLASSIFICATIONS ECl@ss 5.0 27270902 ECl@ss 5.1.4 27270902 ECl@ss 6.0 27270902 ECl@ss 6.2 27270902 ECl@ss 7.0 27270902 ECl@ss 8.0 27270902 ECl@ss 8.1 27270902 ECl@ss 9.0 27270902 ECl@ss 10.0 27270902 ECl@ss 11.0 27270902 ETIM 5.0 EC002717 ETIM 6.0 EC002717 ETIM 7.0 EC002717 UNSPSC 16.0901 39121528

Other Recommended Products SICK