SICK 6036922 type: UM30-212118 Ultrasonic sensor

Access stock, delivery and price for SICK 6036922 type: UM30-212118 Ultrasonic sensor with SICK. SICK, 6036922, SICK 6036922, type:, SICK type:, 6036922 type:, SICK 6036922 type:
To get an offer now: info@imtekmuhendislik.com
Product number UM30-212118
Producer SICK

Description: UM30-212118 ( SICK )

SICK 6036922 type: UM30-212118 Ultrasonic sensor



Product Name: SICK 6036922 type: UM30-212118 Ultrasonic sensor
Product Brand: SICK
Product Code: UM30-212118
Product Artikel: SICK 6036922 type: UM30-212118 Ultrasonic sensor
MECHANICS/ELECTRONICS Supply voltage V s DC 9 V ... 30 V  1)   2) Power consumption ≤ 2.4 W  3) Initialization time < 300 ms Design Cylindrical Housing material Nickel-plated brass, PBT Display: TPU Ultrasonic transducer: polyurethane foam, glass epoxy resin Connection type Male connector, M12, 5-pin Indication LED display, 2 x LED Weight 150 g Sending axis Straight Enclosure rating IP65 / IP67 Protection class III 1)  Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2. 2)  When using the analog voltage output. 3)  Without load. PERFORMANCE Operating range, limiting range 65 mm ... 350 mm, 600 mm Target Natural objects Resolution ≥ 0.18 mm Repeatability ± 0.15 %  1) Accuracy ± 1 %  1)   2) Temperature compensation ✔ Response time 64 ms  3) Switching frequency 12 Hz Output time 16 ms Ultrasonic frequency (typical) 400 kHz Detection area (typical) See diagrams Additional function Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, reset to factory default 1)  Referring to current measurement value. 2)  Temperature compensation can be switched off, without temperature compensation: 0.17 % / K. 3)  Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %. INTERFACES Digital output Number 1  1) Type PNP Maximum output current I A ≤ 200 mA Analog output Number 1 Type Power output / voltage output Function Automatic selection of analog current or voltage output dependent on load Current 4 mA ... 20 mA, ≤ 500 Ω  2) Voltage 0 V ... 10 V, ≥ 100,000 Ω Resolution 12 bit Multifunctional input (MF) 1 x MF Hysteresis 5 mm 1)  PNP: HIGH = V S  - (< 2 V) / LOW = 0 V. 2)  For 4 mA ... 20 mA and V s  ≤ 20 V max. load ≤ 100 Ω. AMBIENT DATA Ambient temperature operation –25 °C ... +70 °C Ambient storage temperature –40 °C ... +85 °C CLASSIFICATIONS ECl@ss 5.0 27270804 ECl@ss 5.1.4 27270804 ECl@ss 6.0 27270804 ECl@ss 6.2 27270804 ECl@ss 7.0 27270804 ECl@ss 8.0 27270804 ECl@ss 8.1 27270804 ECl@ss 9.0 27270804 ETIM 5.0 EC001846 ETIM 6.0 EC001846 UNSPSC 16.0901 41111960

Other Recommended Products SICK