SICK 6049678 TYPE: UFN3-70B413 Fork sensor

Access stock, delivery and price for SICK 6049678 TYPE: UFN3-70B413 Fork sensor with SICK. SICK, 6049678, SICK 6049678, TYPE:, SICK TYPE:, 6049678 TYPE:, SICK 6049678 TYPE:, UFN3-70B413
To get an offer now: info@imtekmuhendislik.com
Product number UFN3-70B413
Producer SICK

Description: UFN3-70B413 ( SICK )

SICK 6049678 TYPE: UFN3-70B413 Fork sensor



Product Name: SICK 6049678 TYPE: UFN3-70B413 Fork sensor
Product Brand: SICK
Product Code: UFN3-70B413
Product Artikel: SICK 6049678 TYPE: UFN3-70B413 Fork sensor
FEATURES Functional principle Ultrasonic detection principle Dimensions (W x H x D) 18 mm x 47.5 mm x 92.5 mm Housing design (light emission) Fork shaped Fork width 3 mm Fork depth 69 mm Minimum detectable object (MDO) Gap between Labels / Size of labels: 2 mm  1) Label detection ✔ Adjustment Plus/minus button (Teach-in, sensitivity, light/dark switching) Teach-in mode 2-point teach-in Teach-in dynamic Output function Light/darkswitching, selectable via button 1)  Depends on the label thickness. MECHANICS/ELECTRONICS Supply voltage 10 V DC ... 30 V DC  1) Ripple 2) Power consumption 40 mA  3) Switching frequency 1.5 kHz  4) Response time 250 µs  5) Switching output PNP, NPN Switching output (voltage) PNP: HIGH = V S – ≤ 2 V / LOW approx. 0 V NPN: HIGH = approx. V S  / LOW ≤ 2 V Switching output Light/dark switching Output current I max. 100 mA  6) Initialization time 100 ms Connection type Male connector M8, 4-pin Protection class III  7) Circuit protection Output Q short-circuit protected Interference pulse suppression Enclosure rating IP65 Weight 95 g Housing material Metal, Aluminum 1)  Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A. 2)  May not exceed or fall below U v  tolerances. 3)  Without load. 4)  With light/dark ratio 1:1, typical, depending on material and speed. 5)  Signal transit time with resistive load. 6)  Output current minimal 0.03 mA. 7)  Reference voltage DC 50 V. AMBIENT DATA Ambient operating temperature +5 °C ... +55 °C  1) Ambient storage temperature –20 °C ... +70 °C Shock load According to EN 60068-2-27 EMC EN 60947-5-2  2) UL File No. NRKH.E191603 & NRKH7.E191603 1)  Do not bend below 0 °C. 2)  The UFN complies with the Radio Safety Requirements (EMC) for the industrial sector (Radio Safety Class A). It may cause radio interference if used in residential areas. CLASSIFICATIONS ECl@ss 5.0 27270909 ECl@ss 5.1.4 27270909 ECl@ss 6.0 27270909 ECl@ss 6.2 27270909 ECl@ss 7.0 27270909 ECl@ss 8.0 27270909 ECl@ss 8.1 27270909 ECl@ss 9.0 27270909 ETIM 5.0 EC002720 ETIM 6.0 EC002720 UNSPSC 16.0901 39121528

Other Recommended Products SICK