SICK 6024915 type: UE48-2OS2D2 Safety relay

Access stock, delivery and price for SICK 6024915 type: UE48-2OS2D2 Safety relay with SICK. SICK, 6024915, SICK 6024915, type:, SICK type:, 6024915 type:, SICK 6024915 type:, UE48-2OS2D2
To get an offer now: info@imtekmuhendislik.com
Product number UE48-2OS2D2
Producer SICK

Description: UE48-2OS2D2 ( SICK )

SICK 6024915 type: UE48-2OS2D2 Safety relay



Product Name: SICK 6024915 type: UE48-2OS2D2 Safety relay
Product Brand: SICK
Product Code: UE48-2OS2D2
Product Artikel: SICK 6024915 type: UE48-2OS2D2 Safety relay
SAFETY-RELATED PARAMETERS Safety integrity level SIL3 (IEC 61508) SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) B 10d  parameter 1.26 x 10 6  switching cycles (AC-15, 230 V, I = 1.5 A) 5.9 x 10 6  switching cycles (AC-15, 230 V, I = 0.75 A) 4.35 x 10 5  switching cycles (DC-13, 24 V, I = 2.5 A) 1 x 10 7  switching cycles (DC-13, 24 V, I = 0.63 A) PFH D  (mean probability of a dangerous failure per hour) 3.0 x 10 -8  (EN ISO 13849) T M  (mission time) 20 years (EN ISO 13849) Stop category 0 (EN 60204-1) INTERFACES Connection type Fixed screw terminals Number of enabling current paths (N/O) 2, relevant for safety ELECTRICAL DATA - OPERATING DATA Voltage supply A1, A2 Output circuit > 25 V AC / 60 V DC PELV Output circuit ≤ 25 V AC / 60 V DC PELV or SELV Supply voltage V s A1, A2 24 V AC/DC (20.4 V AC/DC ... 26.4 V AC/DC) Residual ripple ≤ 2.4 V pp   1) Power consumption (≤ 4.6 VA (AC)) (≤ 2.1 W (DC)) Overvoltage category II Rated insulation voltage U i 300 V AC Rated impulse withstand voltage U imp 4 kV Test voltage 2 kV (50 Hz) (EN 60439-1) 1)  In DC operation, within the limits of V S . ELECTRICAL DATA - CONTROL VOLTAGE: S11, S21, S33 Control voltage 22 V DC (≥ 17.4 V DC) Control current 40 mA ... 100 mA Short-circuit current ≤ 300 mA, between S33 / S11 and S21 Short-circuit protection Electronic fuse Galvanized decoupling – (between A1, A2 and S11, S21, S33) ELECTRICAL DATA - INPUT CIRCUITS: S12, S22, S31, S34, S35 Input voltage HIGH 17.4 V DC ... 26.4 V DC LOW –3 V DC ... 5 V DC Input current S12, S22, S31 ≤ 100 mA S34, S35 ≤ 50 mA Reset time Manual ≤ 40 ms Automatic ≤ 80 ms Activation time of reset button ≥ 50 ms Test pulse width ≤ 1,000 µs Test pulse rate ≤ 10 Hz Cable resistance ≤ 35 Ω ELECTRICAL DATA - OUTPUT CURRENT PATHS: 13/14, 23/24, 31/32, 33/34 Response time ≤ 25 ms  1) Number of enabling current paths (N/O) 2, relevant for safety Number of signaling current paths (N/C) 1, not safety-relevant Contact type Positively driven Contact material Silver alloy, gold flashed Switching voltage Enabling current path 10 V AC ... 230 V AC 10 V DC ... 300 V DC Signaling current path 10 V AC ... 230 V AC 10 V DC ... 300 V DC Current-carrying capacity per OSSD Enabling current path 10 mA ... 6 A Signaling current path 10 mA ... 6 A Total current ≤ 12 A Usage category AC-15/DC-13 (EN 60947-5-1) Rated operating current (voltage) 4 A (230 V AC) 360 switching cycles/h 3 A (230 V AC) 3600 switching cycles/h 4 A (24 V DC) 360 switching cycles/h 2.5 A (24 V DC) 3600 switching cycles/h Switching frequency ≤ 3600/h Mechanical life (relay contacts) 1 x 10 7  switching cycles Electrical life (relay contacts) 2 x 10 6  switching cycles 1)  K1/K2. MECHANICAL DATA Dimensions (W x H x D) 22.5 mm x 114 mm x 96.5 mm Weight 0.21 kg CLASSIFICATIONS ECl@ss 5.0 27371990 ECl@ss 5.1.4 27371990 ECl@ss 6.0 27371819 ECl@ss 6.2 27371819 ECl@ss 7.0 27371819 ECl@ss 8.0 27371819 ECl@ss 8.1 27371819 ECl@ss 9.0 27371819 ECl@ss 10.0 27371819 ECl@ss 11.0 27371819 ETIM 5.0 EC001449 ETIM 6.0 EC001449 ETIM 7.0 EC001449 UNSPSC 16.0901 41113704

Other Recommended Products SICK