SICK 1052071 type: LFP0600-G1NMB Level sensor

Access stock, delivery and price for SICK 1052071 type: LFP0600-G1NMB Level sensor with SICK. SICK, 1052071, SICK 1052071, type:, SICK type:, 1052071 type:, SICK 1052071 type:, LFP0600-G1NMB
To get an offer now: info@imtekmuhendislik.com
Product number LFP0600-G1NMB
Producer SICK

Description: LFP0600-G1NMB ( SICK )

SICK 1052071 type: LFP0600-G1NMB Level sensor



Product Name: SICK 1052071 type: LFP0600-G1NMB Level sensor
Product Brand: SICK
Product Code: LFP0600-G1NMB
Product Artikel: SICK 1052071 type: LFP0600-G1NMB Level sensor
FEATURES Medium Fluids Measurement Switch, Continuous Design Standard Probe length 600 mm Process pressure –1 bar ... 16 bar Process temperature –20 °C ... +150 °C UL approval ✔ RoHS certificate ✔ IO-Link ✔ EHEDG approval ✔ PERFORMANCE Accuracy of sensor element ± 5 mm Reproducibility ≤ 2 mm Resolution < 2 mm Response time < 400 ms  1) Dielectricity constant ≥ 5 for rod probe ≥ 1.8 with coaxial tube Conductivity No limitation Deactivated area at process connection 25 mm  2) Deactivated area at end of probe ≥ 10 mm  3) MTTF 194.3 years (EN ISO 13849-1) 1)  Dependent on measuring mode (high speed < 400 ms, high accuracy < 2,800 ms). 2)  With parameterized container with water under reference conditions, otherwise 40 mm. 3)  With water under reference conditions. ELECTRONICS Supply voltage 12 V DC ... 30 V DC  1) Power consumption ≤ 75 mA at 24 V DC without output load Initialization time ≤ 2 s Protection class III Connection type Round connector M12 x 1, 5-pin Output signal 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V Output load 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 0 V ... 10 V > 750 Ohm at Uv 14 ≥ V Hysteresis Min. 2 mm, free adjustable Signal voltage HIGH V s  - 2 V Signal voltage LOW ≤ 2 V Output current < 100 mA Inductive load < 1 H Capacitive load < 100 nF Enclosure rating IP67: EN 60529, IP69K: ISO 20653 Temperature drift < 0.1 mm/K Lower signal level 3.8 mA ... 4 mA, 0 V Upper signal level 20 mA ... 20.5 mA, 10.5 V EMC EN 61326-2-3, 2014/30/EU 1)  All connections are polarity protected. All outputs are overload and short-circuit protected. MECHANICS Wetted parts 316L (Ra ≤ 0,8 µm), PEEK Process connection G ¾ A Housing material 303 Housing design With viewing window made from PMMA (acrylic glass) Max. probe load ≤ 6 Nm AMBIENT DATA Ambient operating temperature –20 °C ... +60 °C Ambient storage temperature –40 °C ... +80 °C Outdoor use Only with weather hood CLASSIFICATIONS ECl@ss 5.0 27371813 ECl@ss 5.1.4 27371813 ECl@ss 6.0 27371813 ECl@ss 6.2 27371813 ECl@ss 7.0 27371813 ECl@ss 8.0 27371813 ECl@ss 8.1 27371813 ECl@ss 9.0 27371813 ETIM 5.0 EC001447 ETIM 6.0 EC001447 UNSPSC 16.0901 41113710

Other Recommended Products SICK