Goyen ISP-ACAC40-PCA Sensor

Access stock, delivery and price for Goyen ISP-ACAC40-PCA Sensor with Goyen. Goyen, ISP-ACAC40-PCA, Goyen ISP-ACAC40-PCA, , Goyen , ISP-ACAC40-PCA , Goyen ISP-ACAC40-PCA , Sensor
To get an offer now: info@imtekmuhendislik.com
Product number ISP-ACAC40-PCA
Producer Goyen

Description: ISP-ACAC40-PCA ( Goyen )

Goyen ISP-ACAC40-PCA Sensor



Product Name: Goyen ISP-ACAC40-PCA Sensor
Product Brand: Goyen
Product Code: ISP-ACAC40-PCA
Product Artikel: Goyen ISP-ACAC40-PCA Sensor
Integrato Sequencer DP AC-IN AC-OUT 40-0/P Polycarbonate Enclosure ATEX with dP sensor The Integrato Sequencer (IS & ISP) features integrated controls intended for use with larger reverse pulse jet filter cleaning systems. The IS & ISP have been designed to operate across a wide range of environmental conditions. It is suitable for use with all types of filters, including bags, cartridges, sintered metal or ceramic filters. ISP has a built-in differential pressure sensor, allowing this sequencer to be demand driven Features & Specifications: DP SUPPORT : 0 to 4.5 kPa INPUT VOLTAGE AC: 100/240 V @ 50/60 Hz OUTPUT VOLTAGE AC: 100/240 V @ 50/60 Hz (same as input), DC: 24 V MAXIMUM INPUT POWER : AC IN, AC OUT Model: 225 W, AC IN, DC OUT Model: 65 W DISCRETE SOLENOID OUTPUTS : 12, 20 or 40 outputs ENCLOSURE : Polycarbonate or no enclosure PROTECTION RATING (LARGE ENCLOSURE) : Polycarbonate: IP 66/67 & NEMA 1, 3, 3S, 4, 4X, 6, 6P & 12 PROTECTION RATING (SMALL ENCLOSURE) : Polycarbonate: IP65 & NEMA 1, 4, 4X, 12 & 13 OPERATING TEMPERATURE : −40°C to 60°C (−40°F to 140°F) ON & OFF TIME ON : 30 ms to 1000 ms, OFF: 1 s to 1000 s INPUTS Voltage Free : Fan Stop, Low Header Alarm OUTPUTS Voltage Free : Coil Error Analogue Output : 4–20 mA dP signal on the ISP Low temperature operation −40°C (−40°F) Automatic valve detection. Voltage-free coil error output and a visual indication on the display showing which pilot valve output has an error, enabling quick fault finding and debugging. Controls up to 40 pilot valves. Each AC output can have 10 pilot valves connected in parallel, enabling up to 400 pilot valves to be supported. Each DC output can have 3 pilot valves connected in parallel between −20°C to 60°C (−4°F to 140°F), enabling up to 120 pilot valves to be supported and 2 pilot valves connected in parallel between −40°C to 60°C (−40°F to 140°F), enabling up to 80 pilot valves to be supported. Conforms to the requirements of UL, CE, FCC and RCM.

Other Recommended Products Goyen