imtekmuhendislik.com

BECKHOFF KS3403 3-phase power measurement terminal

BECKHOFF

Product number: KS3403
Producer: BECKHOFF
Confirmed Rating: ☆☆☆☆☆☆ (4.7)
Rating Count: 3469

You can fill in the online quotation form or get in touch with Live Support Team for the BECKHOFF brand, KS3403 product. We will get back to you as soon as possible.
PLEASE MAIL TO: info@imtekmuhendislik.com

Datasheets for BECKHOFF KS3403 3-phase power measurement terminal

Description for BECKHOFF KS3403 3-phase power measurement terminal

KL3403 | 3-phase power measurement terminalThe KL3403 Bus Terminal enables the measurement of all relevant electrical data of the supply network. The voltage is measured via the direct connection of L1, L2, L3 and N. The current of the three phases L1, L2 and L3 is fed via simple current transformers. All measured currents and voltages are available as root-mean-square values. In the KL3403 version, the effective power and the energy consumption for each phase are calculated. Through the relationship of the root-mean-square values of voltage U * current I and the effective power P, all other information such as the apparent power S or the phase shift angle cos φ can be derived. For each fieldbus, KL3403 provides a comprehensive network analysis and an energy management option.Technical dataKL3403 | KS3403Number of inputs3 phases + NTechnology3-phase connection techniqueMeasured valuescurrent, voltage, effective power, energy, cos φ, peak values U, I and P, frequencyMeasuring voltagemax. 500 V AC 3~ (ULX-N: max. 288 V AC)Resolution16 bit (21 bit, internal)Measuring currentmax. 1 A, via measuring transformers x A/1 AMeasuring error0.5 % relative to full scale value (U, I), 1 % calculated valueMeasuring proceduretrue RMS with 64,000 samples/sUpdate time50 ms per measured value preset, free configurableElectrical isolation1,500 V (K-bus/field potential)Current consumption power contacts– (no power contacts)Current consumpt. K-bustyp. 115 mABit width in the process imageinput/output: 3 x 16 bit data, 3 x 8 bit control/statusSpecial featuresenergy meter, power measurement, True RMSWeightapprox. 75 gOperating/storage temperature-25…+60 °C/-40…+85 °CRelative humidity95 %, no condensationVibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4Protect. class/installation pos.IP 20/variablePluggable wiringfor all KSxxxx Bus TerminalsApprovalsCE, ULSpecial terminalsKL3403-00103-phase power measurement terminal, current path designed for 5 A transducer (1 % measuring accuracy I),operating/storage temperature: -25…+60 °C/-40…+85 °CKL3403-00203-phase power measurement terminal, current path designed for 20 mA, optimised for electronic current transformer,operating/storage temperature: 0…+55 °C/-25…+85 °CKL3403-00223-phase power measurement terminal, current path and voltage input designed for 20 mA,operating/storage temperature: 0…+55 °C/-25…+85 °CKL3403-03333-phase power measurement terminal, 500 V AC, 333 mV AC,operating/storage temperature: 0…+55 °C/-25…+85 °C

Latest Comments for BECKHOFF KS3403 3-phase power measurement terminal


Other Recommended Products BECKHOFF


BECKHOFF CP9035-M030
BECKHOFF EL1502 Up/Down Counter 24 V DC, 100 kHz
BECKHOFF AL2520-0000
BECKHOFF EP2318-0001
BECKHOFF AT2020-0250
BECKHOFF ES1024
BECKHOFF EPP2809-0021
BECKHOFF ES4021
BECKHOFF ZK4000-2410-2300
BECKHOFF IP1010-B730
BECKHOFF CP6233-0000-0060
BECKHOFF ZK4724-0410-2010
BECKHOFF IP2021-B520
BECKHOFF TF6100-0040
BECKHOFF ZK4704-0411-2010
BECKHOFF ET9402
BECKHOFF CX2040-N031-0003
BECKHOFF CP9035-W008
BECKHOFF EP2008-0022
BECKHOFF C5102-0070
BECKHOFF TS1500-0003
BECKHOFF CX1100-0900
BECKHOFF C9900-E899
BECKHOFF IL2301-C900
BECKHOFF AL3818-0000-0000
BECKHOFF EL9508 Power supply terminal 8 V DC
BECKHOFF EL4732 2-channel analog output terminal
BECKHOFF IP6022-B518
BECKHOFF ZS5100-xxxx
BECKHOFF BZ1102
BECKHOFF C9900-K291
BECKHOFF AG2800-+HDV025Z-MF2-16-wE1-AM884x
BECKHOFF CP9035-V006
BECKHOFF TC1210-0070
BECKHOFF AM8061-wJy0
BECKHOFF TS5111-0002