BECKHOFF KS1501 Up/down counter 24 V DC, 100 kHz

Access stock, delivery and price for BECKHOFF KS1501 Up/down counter 24 V DC, 100 kHz with BECKHOFF. BECKHOFF, KS1501, BECKHOFF KS1501, Up/down, BECKHOFF Up/down, KS1501 Up/down, BECKHOFF KS1501 Up/down
To get an offer now: info@imtekmuhendislik.com
Product number KS1501
Producer BECKHOFF

Description: KS1501 ( BECKHOFF )

BECKHOFF KS1501 Up/down counter 24 V DC, 100 kHz



Product Name: BECKHOFF KS1501 Up/down counter 24 V DC, 100 kHz
Product Brand: BECKHOFF
Product Code: KS1501
Product Artikel: BECKHOFF KS1501 Up/down counter 24 V DC, 100 kHz
KL1501 | Up/down counter 24 V DC, 100 kHz The KL1501 Bus Terminal is an up/down counter. It transmits the counter state to the higher-level automation device in an electrically isolated manner. When it is used as a single-channel up/down counter (32 bit), the pulse is set via the clock input, while the count direction is set via the up/down input. The input can also be used as a gate input for triggering the counter. In two-counter mode, two separate counters (Clock and Clock1 inputs) with each 16  bit are available, which can be parameterised as up or down counters. The signal state of the inputs and outputs is indicated by light emitting diodes. Both outputs are switched according to the counter state, so that they can be used as fast control signals for field devices. Technical data KL1501  | KS1501 Connection technology 1 x up/down counter, 2 x up or down counter Specification EN 61131-2, type 1, “0”: < 5 V DC, “1”: > 15 V DC, typ. 5 mA Number of counters 1 or 2 Nominal voltage 24 V DC (-15 %/+20 %) “0” signal voltage -3…+5 V (EN 61131-2, type 1) “1” signal voltage 15…30 V (EN 61131-2, type 1) Counting frequency max. 100 kHz (2 kHz for switching between up and down) Counter depth 32 bit Input current typ. 5 mA (EN 61131-2, type 1) Max. output current 24 V/0.5 A (short-circuit proof) per channel Current consumption K-bus typ. 50 mA Current consumption power contacts load only Electrical isolation 500 V (K-bus/field potential) Bit width in the process image 40 inputs/outputs: 32 bit data, 8 bit control/status Configuration no address setting, configuration via Bus Coupler or controller Special features set counters, switch outputs Weight approx. 50 g Operating/storage temperature -25…+60 °C/-40…+85 °C Relative humidity 95 %, no condensation Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27 EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4 Protect. class/installation pos. IP 20/variable Pluggable wiring for all KSxxxx Bus Terminals Approvals CE, UL, Ex, IECEx Special terminals KL1501-0010 gate-counter with auto-reset and setting A0 KL1501-0011 up/down counter with 5 V inputs, 24 V DC outputs

Other Recommended Products BECKHOFF