BECKHOFF KL9050 Terminal Bus Extension, Coupler Terminal

Access stock, delivery and price for BECKHOFF KL9050 Terminal Bus Extension, Coupler Terminal with BECKHOFF. BECKHOFF, KL9050, BECKHOFF KL9050, , BECKHOFF , KL9050 , BECKHOFF KL9050
To get an offer now: info@imtekmuhendislik.com
Product number KL9050
Producer BECKHOFF

Description: KL9050 ( BECKHOFF )

BECKHOFF KL9050 Terminal Bus Extension, Coupler Terminal



Product Name: BECKHOFF KL9050 Terminal Bus Extension, Coupler Terminal
Product Brand: BECKHOFF
Product Code: KL9050
Product Artikel: BECKHOFF KL9050 Terminal Bus Extension, Coupler Terminal
The KL9050 coupler terminal replaces the Bus Coupler on a Bus Terminal block. The KL9050 is the counterpart to the KL9020. The S(F)TP cable (shielded twisted pair) is plugged into the upper socket, providing the logical connection to the Bus Coupler. The extension is fully transparent for the Bus Coupler. All Bus Terminal system functions remain unchanged. The second RJ45 socket allows the system to be extended further. A new KL9050 can be connected to the first coupler terminal. The whole system can thereby be extended by 31 stations. The supply voltage for the field level and the internal electronics can be input separately. Both levels are thereby electrically isolated from one another. In the KL9050 a 400 mA K-bus power supply unit supplies the added Bus Terminals. The internal electronics and the field level can be supplied together from a single voltage source. Three diagnostic LEDs give information about the supply voltage for each Bus Terminal block, internal and field level. The KL9050 can be used as the last coupler terminal in the system or as a bridge between two Bus Terminal blocks. You can switch between these two functions with a selector switch. The switch must be correctly positioned for the system to operate. Technical data KL9050 Number of Bus Terminals 64 Current load ≤ 10 A Power LED green Defect LED – Type/number of peripheral signals Bus Coupler dependency Distance between stations max. 5 m between KL9050 and KL9050 Bus interface 2 x RJ45 socket (input + output) Power supply 24 V DC (-15 %/+20 %) Input current 70 mA + (total K-bus current)/4, 200 mA max. Starting current 2.5 x continuous current Current consumption K-bus typ. 70 mA + (total K-bus current)/4, max. 200 mA Current supply K-bus up to 400 mA Power contacts 24 V DC max./10 A max. Nominal voltage 24 V DC (-15 %/+20 %) Electrical isolation 500 V (power contact/supply voltage/fieldbus) PE contact yes Shield connection – Electrical connection to DIN rail – Special features coupler terminal for K-bus extension (max. 64 Bus Terminals) Weight approx. 75 g Operating/storage temperature 0…+55 °C/-25…+85 °C Relative humidity 95 %, no condensation Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27 EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4 Protect. class/installation pos. IP 20/variable Approvals CE, UL, Ex, GL

Other Recommended Products BECKHOFF