BECKHOFF KL1501 Up/down Counter

BECKHOFF

Product number: KL1501
Producer: BECKHOFF
Confirmed Rating: ☆☆☆☆☆ (3.6)
Rating Count: 8352

You can fill in the online quotation form or get in touch with Live Support Team for the BECKHOFF brand, KL1501 product. We will get back to you as soon as possible.
PLEASE MAIL TO: info@imtekmuhendislik.com

Datasheets for BECKHOFF KL1501 Up/down Counter

Description for BECKHOFF KL1501 Up/down Counter

The KL1501 Bus Terminal is an up/down counter. It transmits the counter state to the higher-level automation device in an electrically isolated manner. When it is used as a single-channel up/down counter (32 bit), the pulse is set via the clock input, while the count direction is set via the up/down input. The input can also be used as a gate input for triggering the counter. In two-counter mode, two separate counters (Clock and Clock1 inputs) with each 16  bit are available, which can be parameterised as up or down counters. The signal state of the inputs and outputs is indicated by light emitting diodes. Both outputs are switched according to the counter state, so that they can be used as fast control signals for field devices.Technical dataKL1501 | KS1501Connection technology1 x up/down counter, 2 x up or down counterSpecificationEN 61131-2, type 1, “0”: < 5 V DC, “1”: > 15 V DC, typ. 5 mANumber of counters1 or 2Nominal voltage24 V DC (-15 %/+20 %)“0” signal voltage-3…+5 V (EN 61131-2, type 1)“1” signal voltage15…30 V (EN 61131-2, type 1)Counting frequencymax. 100 kHz (2 kHz for switching between up and down)Counter depth32 bitInput currenttyp. 5 mA (EN 61131-2, type 1)Max. output current24 V/0.5 A (short-circuit proof) per channelCurrent consumption K-bustyp. 50 mACurrent consumption power contactsload onlyElectrical isolation500 V (K-bus/field potential)Bit width in the process image40 inputs/outputs: 32 bit data, 8 bit control/statusConfigurationno address setting, configuration via Bus Coupler or controllerSpecial featuresset counters, switch outputsWeightapprox. 50 gOperating/storage temperature-25…+60 °C/-40…+85 °CRelative humidity95 %, no condensationVibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4Protect. class/installation pos.IP 20/variablePluggable wiringfor all KSxxxx Bus TerminalsApprovalsCE, UL, Ex, IECEx

Latest Comments for BECKHOFF KL1501 Up/down Counter


Other Recommended Products BECKHOFF


BECKHOFF TF6281-0050
BECKHOFF CP2911-0000
BECKHOFF ZK1031-6400-1100
BECKHOFF AM8072-wPy1
BECKHOFF BC3150
BECKHOFF AM8562-wNyB
BECKHOFF CP6232-0000-0050
BECKHOFF TS6280-0003
BECKHOFF C9900-H567
BECKHOFF C9900-K123
BECKHOFF IE2301
BECKHOFF C9900-E515
BECKHOFF AX2526-B750-0000
BECKHOFF C9900-K624
BECKHOFF TS6250-0005
BECKHOFF ET9400
BECKHOFF TS3300-0004
BECKHOFF CP6231-0001-0060
BECKHOFF TC1275-0070
BECKHOFF C9900-M120
BECKHOFF CP7203-0000-0050
BECKHOFF ZK4509-0004-zzzz
BECKHOFF ERI2809-0022
BECKHOFF EPP9001-0060
BECKHOFF IP2000-B510
BECKHOFF ZS4000-2102
BECKHOFF ZK1090-3132-1100
BECKHOFF TF6340-0030
BECKHOFF TF6310-0030
BECKHOFF AT9011-1441
BECKHOFF ZK1090-3131-0006
BECKHOFF KL9100 Potential Aupply Terminal, 24 V DC
BECKHOFF C6640-0040
BECKHOFF TS6370-0004
BECKHOFF C9900-B500
BECKHOFF C9900-S443