HEIDENHAIN LIC 4199 Y Exposed Linear Encoder

Access stock, delivery and price for HEIDENHAIN LIC 4199 Y Exposed Linear Encoder with HEIDENHAIN. HEIDENHAIN, LIC, HEIDENHAIN LIC, 4199, HEIDENHAIN 4199, LIC 4199, HEIDENHAIN LIC 4199
To get an offer now: info@imtekmuhendislik.com
Product number LIC 4199 Y
Producer HEIDENHAIN

Description: LIC 4199 Y ( HEIDENHAIN )

HEIDENHAIN LIC 4199 Y Exposed Linear Encoder



Product Name: HEIDENHAIN LIC 4199 Y Exposed Linear Encoder
Product Brand: HEIDENHAIN
Product Code: LIC 4199 Y
Product Artikel: HEIDENHAIN LIC 4199 Y Exposed Linear Encoder
Scale LIC 4009 Measuring standard Coefficient of linear expansion Steel scale tape with absolute and incremental METALLUR track α therm  10 · 10 –6 K –1 Accuracy grade * ±3 µm, ±15 µm 1) Baseline error ≤ ±0.750 µm/50 mm (typical) Measuring length (ML) * in mm 70 120 170 220 270 320 370 420 520 620 720 820 920 1020 Mass 31 g/m Scanning head LIC 411 LIC 419 F LIC 419 M LIC 419 P LIC 419 Y Interface EnDat 2.2 Fanuc Serial Interface α i Mitsubishi high speed interface Panasonic Serial Interface Yaskawa Serial Interface Ordering designation* EnDat22 Fanuc05 Mit03-4 Mit02-2 Pana01 YEC07 Measuring step* 0.01 µm (10 nm) 0.005 µm (5 nm) 0.001 µm (1 nm) 2) Calculation time t cal Clock frequency ≤ 5 µs ≤ 16 MHz – Traversing speed 3) ≤ 600 m/min Interpolation error ±20 nm Electrical connection * Cable, 1 m or 3 m, with 8-pin M12 coupling (male) or 15-pin D-sub connector (male) Cable length (with HEIDENHAIN cable) ≤ 100 m 4) ≤ 50 m ≤ 30 m ≤ 50 m Supply voltage DC 3.6 V to 14 V Power consumption 3) (max.) At 3.6 V: ≤ 700 mW At 14 V: ≤ 800 mW At 3.6 V: ≤ 850 mW At 14 V: ≤ 950 mW Current consumption (typical) At 5 V: 75 mA (without load) At 5 V: 95 mA (without load) Vibration 55 Hz to 2000 Hz Shock 6 ms ≤ 500 m/s 2 (EN 60068-2-6) ≤ 1000 m/s 2 (EN 60068-2-27) Operating temperature –10 °C to 70 °C Mass Scanning head Connecting cable Connecting element ≤ 18 g (without cable) 20 g/m M12 coupling: 15 g; D-sub connector: 32 g * Please select when ordering 1) ±5 µm after linear length-error compensation in the evaluation electronics 2) Mitsubishi: measuring length ≤ 2040 mm Yaskawa: measuring length ≤ 1840 mm 3) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure 4) With LIC 411 FS scanning head: clock frequency: 8 MHz

HEIDENHAIN LIC 4193 F Exposed Linear Encoder

HEIDENHAIN LIC 4193 M Exposed Linear Encoder

HEIDENHAIN LIC 4193 P Exposed Linear Encoder

HEIDENHAIN LIC 4193 Y Exposed Linear Encoder

HEIDENHAIN LIC 4195 M Exposed Linear Encoder

HEIDENHAIN LIC 4195 P Exposed Linear Encoder

HEIDENHAIN LIC 4195 Y Exposed Linear Encoder

HEIDENHAIN LIC 4197 F Exposed Linear Encoder

HEIDENHAIN LIC 4197 M Exposed Linear Encoder

HEIDENHAIN LIC 4197 P Exposed Linear Encoder

HEIDENHAIN LIC 4197 Y Exposed Linear Encoder

HEIDENHAIN LIC 4199 F Exposed Linear Encoder

HEIDENHAIN LIC 4199 M Exposed Linear Encoder

HEIDENHAIN LIC 4199 P Exposed Linear Encoder

HEIDENHAIN LIC 4199 Y Exposed Linear Encoder

HEIDENHAIN LIC 4009 FS Exposed Linear Encoder

HEIDENHAIN LIC 2197 F Exposed Linear Encoder

HEIDENHAIN LIC 2197 M Exposed Linear Encoder

HEIDENHAIN LIC 2197 P Exposed Linear Encoder

HEIDENHAIN LIC 2197 Y Exposed Linear Encoder

HEIDENHAIN LIC 2199 F Exposed Linear Encoder

HEIDENHAIN LIC 2199 M Exposed Linear Encoder

HEIDENHAIN LIC 2199 P Exposed Linear Encoder

HEIDENHAIN LIC 2199 Y Exposed Linear Encoder

Other Recommended Products HEIDENHAIN