Scale | LIC 4005 |
Measuring standard Coefficient of linear expansion | Steel scale tape with absolute and incremental METALLUR track Depends on the mounting surface |
Accuracy grade | ±5 µm |
Baseline error | ≤ ±0.750 µm/50 mm (typical) |
Measuring length (ML)* in mm | 140 240 340 440 540 640 740 840 940 1040 1140 1240 1340 1440 1540 1640 1740 1840 1940 2040 |
Greater measuring lengths of up to 28 440 mm with a single-section scale tape and individual scale carrier sections |
Mass Scale tape Parts kit Scale tape carrier | 31 g/m 80 g + n1) · 27 g 187 g/m |
| | | |
Scanning head | LIC 411 | LIC 419 F | LIC 419 M | LIC 419 P | LIC 419 Y |
Interface | EnDat 2.2 | Fanuc Serial Interface αi | Mitsubishi high speed interface | Panasonic Serial Interface | Yaskawa Serial Interface |
Ordering designation* | EnDat22 | Fanuc05 | Mit03-4 | Mit02-2 | Pana01 | YEC07 |
Measuring step* (note measuring length limitation2)) | 0.01 µm (10 nm) 0.005 µm (5 nm) 0.001 µm (1 nm) |
Calculation time tcal Clock frequency | ≤ 5 µs ≤ 16 MHz | – |
Traversing speed3) | ≤ 600 m/min |
Interpolation error | ±20 nm |
Electrical connection* | Cable, 1 m or 3 m, with 8-pin M12 coupling (male) or 15-pin D-sub connector (male) |
Cable length (with HEIDENHAIN cable) | ≤ 100 m | ≤ 50 m | ≤ 30 m | ≤ 50 m |
Supply voltage | DC 3.6 V to 14 V |
Power consumption3) (max.) | At 3.6 V: ≤ 700 mW At 14 V: ≤ 800 mW | At 3.6 V: ≤ 850 mW At 14 V: ≤ 950 mW |
Current consumption (typical) | At 5 V: 75 mA (without load) | At 5 V: 95 mA (without load) |
Vibration 55 Hz to 2000 Hz Shock 6 ms | ≤ 500 m/s2 (EN 60068-2-6) ≤ 1000 m/s2 (EN 60068-2-27) |
Operating temperature | –10 °C to 70 °C |
Mass Scanning head Connecting cable Connecting element | ≤ 18 g (without cable) 20 g/m M12 coupling: 15 g; D-sub connector: 32 g |
* Please select when ordering 1) n = 1 for ML 3140 mm to 5040 mm; n = 2 for ML 5140 mm to 7040 mm; etc.* 2) Mitsubishi: 1 nm: measuring length ≤ 2040 mm; 5 nm: measuring length ≤ 10 040 mm; 10 nm: measuring length ≤ 20 040 mm Yaskawa: 1 nm: measuring length ≤ 1840 mm; 5 nm: measuring length ≤ 9040 mm; 10 nm: measuring length ≤ 18 040 mm 3) See General electrical information in the Interfaces of HEIDENHAIN Encoders brochure |